Key Takeaways
- A facility in Italy chose an SCC STRONG 2S 75: a two-stage, variable-speed screw compressor with 75 kW rated power.
- According to the project team, energy efficiency was the deciding factor.
- The efficiency results from the interplay of two-stage compression, IE5 permanent magnet motor, variable-speed control for main motor and fan, and direct drive.
- According to product documentation, the SCC-C80 controller displays power consumption and cumulative energy demand, making energy requirements visible during operation.
- The machine comes with a 5-year warranty according to the applicable warranty terms.
- Applicable to other facilities: Energy efficiency is not determined by a single feature, but by the interplay—evaluated against your own load profile.
Initial Situation: Efficiency as a Decision Criterion
When selecting a new screw compressor, most compare motor power, delivery volume, and price. However, what matters for operating costs is how much electricity the machine requires for each cubic meter of compressed air.
This was also the key consideration for a facility in Italy. The decision fell on an SCC STRONG 2S 75—according to the project team, because the energy efficiency was convincing.
The Solution: Ten Features of an Energy-Efficient Compressor
The project team in Italy identified ten reasons for choosing the machine, including a favorable ratio of power consumption to delivery volume and low operating costs. The overview shows what lies behind each point:
Ten Selection Criteria and Their Implementation in the SCC STRONG 2S 75
| Auswahlkriterium | Umsetzung beim STRONG 2S 75 |
|---|---|
| Günstiges Verhältnis von Leistung zu Liefermenge | Auslegung auf einen niedrigen spezifischen Leistungsbedarf in kW je m³/min |
| Liefermenge | Liefermengenbereich laut Katalog: 5,69–15,15 m³/min bei 8 bar und 4,53–12,05 m³/min bei 10 bar |
| Effizienzklasse IE5 | Der Hauptmotor erreicht laut Produktunterlagen die Effizienzklasse IE5 |
| Permanentmagnetmotor | Hauptmotor in Permanentmagnet-Bauweise, luftgekühlt, ohne zusätzlichen Ölkreislauf für die Motorkühlung |
| Frequenzumrichter am Hauptmotor | Drehzahl und Liefermenge folgen dem Luftbedarf; Leerlaufzeiten werden reduziert |
| Frequenzumrichter am Lüfter | Die Lüfterdrehzahl folgt dem Kühlbedarf, der von Auslastung und Umgebungstemperatur abhängt |
| Niedrige Drehzahl | Die niedrige Drehzahl der Verdichterstufe trägt laut Produktunterlagen zu geringeren Geräuschemissionen bei |
| Feste Verrohrung | Starre Rohrleitungen führen die Druckluft innerhalb der Maschine |
| Niedrige Betriebskosten | Ziel der Auslegung; wie hoch die Betriebskosten ausfallen, hängt vom Lastprofil ab |
| Garantie | 5 Jahre gemäß den gültigen Garantiebedingungen, Details auf Anfrage |
The delivery volumes are catalog values for the series according to ISO 1217 for the 8 and 10 bar pressure variants. They describe the control range of the machine, not the operating pressure or actual delivery volume on site. The compression stage is driven directly, without V-belts.
Why Compressor Control Matters in the Decision
Efficiency you cannot see is difficult to control. That is why the compressor controller belongs on the selection list. According to product documentation, the SCC-C80 offers two functions that are particularly relevant for operators:
- Make consumption visible: The controller displays power consumption and cumulative energy demand, creating transparency during ongoing operation. To determine specific power requirement, the electrical active power consumption of the entire compressor package and the delivery volume must be recorded simultaneously. A power display alone is not sufficient for this.
- Network systems: Operating data can be transmitted via the Modbus interface; in a network, the C80 operates as master or slave with up to 16 additional compressors. How this helps in daily operation is shown in the article Smart Factory: networked compressors.
Result: Efficiency Was the Deciding Factor
According to the project team, energy efficiency was decisive in choosing the STRONG 2S 75. The two-stage compression, IE5 permanent magnet motor, and demand-based control of main motor and fan were central considerations.
How efficiently the system operates in daily use depends on the load profile and can only be verified through measurement. For the specific energy requirement in kWh per m³, the electrical energy consumed and the total compressed air delivered are recorded over the same period—with uniform measurement boundaries and the same reference basis for volume. Savings can additionally only be quantified against a comparably measured baseline situation. The controller display provides an indication for this, but does not replace this measurement.





What Other Facilities Can Adopt
- Evaluate features in context. An IE5 motor alone does not make an energy-efficient compressor. What matters is the interplay of compression, motor, control, and cooling.
- Compare specific power requirement. Only compare values at the same pressure and comparable operating point—as described in the practical example on specific power requirement with a STRONG 2S 132.
- Check part-load operation. With fluctuating demand, efficiency across the entire control range matters, not just at the best point. When variable-speed control pays off is explained in the article Variable-Speed Compressor: Is VSD Worth It?
- Consider warranty and maintenance. Warranty terms, maintenance schedule and intervals belong in the total cost calculation—as does regular maintenance by SCC.
Frequently Asked Questions
What makes a compressor energy-efficient?
An energy-efficient compressor delivers the required compressed air with the lowest possible electrical power consumption—measurable by specific power requirement in kW per m³/min. Contributing factors include the compression principle, motor efficiency, demand-based control, and economical auxiliary units such as the fan. Equally important are proper sizing and avoiding unnecessarily high pressure levels.
What does a variable-speed fan provide?
It adjusts its speed to the cooling demand, instead of running at fixed speed. Cooling demand depends on utilization, but also on ambient temperature and conditions in the compressor room. When less cooling is needed, the fan can run slower. Because a fan’s power consumption typically decreases disproportionately with decreasing speed, this reduces its electricity consumption.
What warranty applies to the STRONG 2S?
The STRONG 2S comes with a 5-year warranty according to the applicable warranty terms. Details are available upon request.
Finding the Right Energy-Efficient Compressor
Are you planning a new compressor or want to make your compressed air generation more efficient? Tell us the required pressure at the point of use, the necessary delivery volume, your operating hours, and—if known—your load profile. SCC air compressors will review as part of compressed air consulting which series and which control system match your requirements.