Key Points at a Glance
- Four fault patterns point to very different causes: no pressure build-up, slow pressure build-up, pressure drop under load, and a difference between compressor and consumer.
- Record first, then intervene: operating status, message text as shown, operating hours, and the pressure readings at generation and at the consumer—ideally at the same time and under the relevant draw-off.
- A lot can be narrowed down without intervening in the machine—via indicators, differential pressure across the filters, and a check for open drains and valve positions within the scope of site approval.
- Raising the pressure setpoint is not an answer to an unresolved fault. Any adjustment requires a technical assessment, approval, and consideration of the limits of the entire system.
- For a service request, the series and serial number, operating hours, the message text as shown, and the observed pressure trend are sufficient.
Start of shift, the station starts up—and the pressure gauge stays below the usual value. In production, the first machines report insufficient pressure. If you only acknowledge the alarm and restart at this point, you lose time and often overwrite the very information needed to find the cause. This article applies to screw compressors in a fixed compressed-air station, not small piston units in the workshop.
“No pressure” is not a single fault, but an observation that can match several causes. It may be at the machine, the receiver, the air treatment, or the pipework network—and in some cases at the measuring point itself. If this cannot be clarified within a few checks, service is the faster route than another restart attempt.
The following explains how to distinguish the fault patterns, what can be read during operation, and the points at which the system should be stopped.
Four fault patterns, four directions to investigate
The distinction determines where to look. It takes a few minutes and often saves a full troubleshooting process.
1. No pressure builds up
If the drive is running but the pressure still does not rise, the machine may not be operating under load. Oil-injected screw compressors control via an inlet regulator: in idle, the intake side is largely closed, the drive continues to turn, and hardly any air is delivered. Which status the controller displays for this is specified in the machine’s operating manual. The second possibility is an open point in the system—such as a manual drain at a low point, a valve in the wrong position, or a take-off point left open overnight.
2. Pressure rises too slowly
Here the machine is delivering, but the balance does not add up. A clogged intake filter increases resistance on the suction side. Leaks continuously draw air from the network. And in some plants, demand has grown over the years without the delivered volume ever being recalculated—how to properly determine compressed-air demand is a better starting point than an estimate. On belt-driven versions, slip is an additional possible cause.
3. Pressure drops under load
If the pressure drops only during certain operations and then recovers, the issue lies in the interaction of demand profile, usable storage, and control strategy. How long a peak can be covered from the receiver depends on volume, usable pressure range, draw-off, and whether additional air is being delivered at the same time. Whether the machine returns to load or the motor restarts are two different processes with different time constants. This can only be assessed reliably with a measured load profile.
4. Pressure is present at the compressor, but not at the consumer
This observation shifts suspicion toward the network and air treatment—but it does not rule out generation. Only if both gauges are read at the same time and under the draw-off at which the problem occurs can a true pressure differential be separated from a control, capacity, or indication issue. If a differential is then confirmed, the usual loss sources come into play: clogged filters, the dryer, lines that are too long or too small, and hoses and couplings at the consumer. Which components in this chain contribute what is described in the article on compressed-air treatment.

What should be recorded before any intervention
Any change to the setpoint or the system also changes the fault pattern. If you note it beforehand, you do not have to search twice later:
- Series, model designation, and serial number from the nameplate.
- Total operating hours as well as load and idle hours, insofar as the controller provides them.
- Displayed operating status and the exact wording of each message with date and time.
- Pressure reading at generation and at the critical consumer, at the same time and under the relevant draw-off.
- Configured pressure values of the control system and the station’s receiver volume.
- Since when the behavior has been noticeable and what changed beforehand—new machine, network modification, maintenance, filter change.
Read, observe, assign
The following overview helps you classify observations, narrow down possible causes, and coordinate the next step with service.
| Observation | Possible causes | What can be read or observed | When service takes over |
|---|---|---|---|
| The machine is running, but the pressure does not rise. | Idle operation; draw-off above delivered volume; an open take-off point or an open drain. | Read operating status and messages on the controller. Check visible valve and drain positions within the scope of site approval. | If load status is present, no open draw-off is found, and the pressure still does not rise. |
| Pressure rises more slowly than in comparable situations previously. | Higher intake resistance; leaks in the network; increased demand; belt slip on belt-driven units. | Read filter and differential pressure indicators. Compare load and idle hours with earlier values. During a production break, listen for audible leaks. | If wear is suspected on the drive, compressor stage, control valves, or separator. |
| Pressure drops during peak loads and then recovers. | Relationship between demand profile, usable storage, and control strategy; a single large consumer. | Log the time, magnitude, and duration of the drops and assign them to the production process. Compare readings at generation and at the consumer. | If storage, pressure settings, or the distribution across multiple machines needs to be assessed. |
| Pressure is present at the compressor, but missing at the consumer. | Pressure loss across air treatment, lines, hoses, and couplings. A measurement or indication error is also possible. | Read the indicators at generation and at the consumer at the same time and under the relevant draw-off. Record the filters’ differential pressure indicators. | If the differential remains after a filter change, the measurement is unclear, or the network structure is to be modified. |
| The controller displays a message or shuts down. | Warning, maintenance notice, or triggering of a safety function. This cannot be distinguished from occurrence alone. | Record the message text as shown with date, time, and operating hours, and assign it using the operating manual. | Immediately in the event of safety shutdowns and repeated shutdowns. For other messages, follow the machine’s documented response. |
Where the search ends
Some measures restore pressure in the short term but shift the problem—or create a new one:
- Opening pressurized components before the system has been depressurized according to the manufacturer’s instructions and secured against being switched on again.
- Bypassing, adjusting, or blocking safety functions, interlocks, or safety valves.
- Repeatedly acknowledging a shutdown to force operation.
- Raising the pressure setpoint without technical assessment and approval.
- Working on the electrical equipment without the appropriate qualification.
The operating manual for the specific machine is decisive. If a check step there differs from this description, the manufacturer’s specification applies. And if the fault could be caused in the compressor room itself—temperature, supply air, installation—then the checklist for the installation room helps narrow it down.
If the cause is in the network
Raising the setpoint until enough reaches the consumer is common and rarely a solution. Energy demand usually increases as well, leakage losses too, and the cause remains undiscovered. The robust approach goes the other way: the required pressure is defined at the consumer, then tolerances and the actual losses across air treatment and the network are added. How to derive a justified operating pressure from this is described in detail elsewhere.
Condensate is part of the same assessment. A condensate drain that remains permanently open continuously bleeds air from the system and looks like a leak in the pressure trend. How condensate forms in the machine and what it causes there is described separately.
Frequently Asked Questions
May I raise the pressure setpoint until sufficient pressure is available again?
Not as a response to an unresolved fault. Adjusting the setpoint is a technical decision: it requires that the cause has been assessed, that the limits of the machine, receiver, air treatment, and network remain within specification, and that the change is operationally approved. Without these steps, it masks the problem and usually increases energy demand.
How do I tell whether the machine is running in idle?
By the displayed operating status. The label and display vary depending on series and configuration; the binding assignment is given in the machine’s operating manual.
How much leakage is normal?
There is no generally valid value. The question becomes meaningful through measurement in real operation, for example via compressed-air consumption during non-production times. A rule of thumb from another plant does not replace this measurement.
Does the system have to stop immediately for every message?
No—but the message determines that, not a gut feeling. Safety shutdowns and repeated shutdowns should be evaluated before the machine is started again. For warnings and maintenance notices, the response documented in the operating manual applies. The mere occurrence of a message does not indicate which case applies.
Have the fault narrowed down
If the simple checks do not provide a clear picture, a brief technical call usually achieves more than another restart attempt. For an initial assessment, four details are sufficient: series and serial number, operating hours, the message text as shown, and the observed pressure trend with time. This makes it possible to say whether the machine, receiver, or network is more likely to need checking and which measurement would be useful next.