Summary
- An operation in Italy generates its compressed air with an SCC STRONG 2S 132: a two-stage, variable-speed screw compressor with an IE5 permanent magnet motor and a nominal power of 132 kW.
- According to the project team, the focus was on the electrical power consumption of compressed air generation.
- According to the project team, the installation fully met the customer’s expectations.
- The specific power consumption in kW per m³/min – not the nominal power – provides the appropriate benchmark for efficiency.
- Such values are only comparable under the same pressure, comparable operating point, and identical system boundaries.
Starting Point: Compressed Air with Minimal Power
The compression of air requires energy. For an electrically driven compressor, this results in electricity costs. Therefore, according to the project team, the electrical power consumption was the focus for the new compressed air generation at an operation in Italy.
The appropriate benchmark for this is not the motor power on the nameplate, but the specific power consumption. It relates the electrical power consumption of the entire compressor package to the delivered volume flow. This is specified as Free Air Delivery (FAD) under defined reference conditions. The unit for specific power consumption here is kW per m³/min.
The Solution: a STRONG 2S 132
An SCC STRONG 2S 132 was installed. This series combines several features designed for low specific power consumption:
- Two-stage compression: Air is compressed in two stages and cooled in between. This can reduce energy consumption compared to single-stage compression.
- IE5 permanent magnet motor: air-cooled, according to product documentation, without an additional oil circuit for motor cooling.
- Two frequency converters: The main motor adjusts its speed to the air demand, and the fan to the cooling demand.
- Direct drive: without V-belts between motor and compressor stage.
- SCC-C80 control: displays current consumption and cumulative energy consumption, according to product documentation.
Project Overview
SCC STRONG 2S 132 in an Operation in Italy
| Feature | Specification |
|---|---|
| Location | Operation in Italy |
| Compressor | SCC STRONG 2S 132 |
| Design | Oil-injected, two-stage screw compressor |
| Nominal Power | 132 kW |
| Delivery Volume Range according to Catalogue | 9.90–26.39 m³/min at 8 bar; 8.90–23.69 m³/min at 10 bar |
| Motor | IE5 permanent magnet motor, air-cooled |
| Control | Frequency converter for main motor and fan |
| Drive | Direct drive |
| Controller | SCC C80 |
| Warranty | 5 years according to valid warranty conditions, details on request |
The Free Air Delivery (FAD) values are catalogue values for the series according to ISO 1217 for the 8 and 10 bar pressure variants. They describe the machine’s control range, not the operating pressure or the actual Free Air Delivery on site.
Result: Customer Expectations Met
After installation, the project team reported that the STRONG 2S 132 fully met the customer’s expectations. How efficiently a system operates in daily use is shown by the specific power consumption – determined at the real operating point and under the same conditions used for comparison.
How to Read Specific Power Consumption
Specific power consumption is a ratio: electrical power consumption divided by Free Air Delivery, both determined at the same operating point. A calculation example with assumed values, independent of this project: If a compressor at 8 bar consumes 100 kW and delivers 16 m³/min, its specific power consumption is 6.25 kW per m³/min.
If you want to know the energy consumption per cubic metre, convert to kWh per m³: power divided by the hourly Free Air Delivery. In the example, this is 100 kW divided by 960 m³/h, which is approximately 0.104 kWh per m³.
The specification ‘kW per m³’ is incomplete for specific power consumption. It refers to the ratio of electrical power consumption to volume flow, given here in kW per m³/min. The energy consumption per cubic metre generated, however, is given in kWh/m³.








What other companies can adopt
- Compare by specific power consumption, not nominal power. Two compressors with the same motor power can require different amounts of electricity for the same cubic metre. This is also shown in the case study ‘Why 55 kW is not always 55 kW’.
- Demand consistent conditions. Compare values only under the same pressure, comparable operating point, and identical system boundaries. Ask whether frequency converters, fans, and control systems are included, what reference conditions the Free Air Delivery refers to, and which test procedure was used, such as ISO 1217.
- Measure your own system. Record the electrical active power consumption of the entire compressor and the Free Air Delivery simultaneously under real load, over a representative period. The article Measuring Compressed Air Consumption describes how to achieve this.
- Translate differences into costs. An example calculation with assumed values: a difference of 0.5 kW per m³/min results in approximately 40,000 kWh per year for 20 m³/min and 4,000 full-load hours. Multiplied by the electricity price, this yields the additional costs. A separate article shows how to determine the compressed air costs per m³.
The project on energy-efficient compressors of the STRONG 2S series shows how another operation in Italy specifically selected its compressor based on efficiency criteria.
Frequently asked questions
What does specific power consumption mean for a compressor?
It describes the ratio of electrical power consumption to Free Air Delivery (FAD) and is given in kW per m³/min. The lower the value at the same pressure, comparable operating point, and identical system boundaries, the more efficiently the machine operates.
How do you convert kW per m³/min to kWh per m³?
You divide the value by 60. Thus, the 6.25 kW per m³/min in the calculation example above becomes approximately 0.104 kWh per m³. Both values are only valid for the operating point at which power and Free Air Delivery were determined.
Should the compressed air dryer be included in the calculation?
Not in the specific power consumption of the compressor: dryers and further treatment have their own system boundary and are evaluated separately. If the energy consumption of the compressor and treatment is related to the same usable compressed air volume under the same reference conditions, the shares in kWh/m³ can be added. The electricity costs per cubic metre only result when this value is multiplied by the electricity price.
Optimise Your Compressed Air Generation
Would you like to know what specific power consumption is realistic for your application? Let us know the required pressure at the consumer, the necessary Free Air Delivery, your operating hours, and – if available – measurement data for power and volume flow. SCC air compressors will assess, as part of their compressed air consultation, which series and control system suit your load profile. We would also be happy to explain the warranty conditions to you.